Physical
|
|
Max thermal capacity
|
100 MW
|
Core:
|
|
|
1000 mm
|
|
1220 mm
|
- number of cells for standard FAs
|
48
|
- max diameter of a loop channel
|
120 mm
|
- max number of loop channels
|
11
|
Moderator
|
beryllium
|
Reflector
|
beryllium
|
Fuel:
|
UO2
|
|
90 %
|
Neutronic
|
|
Max thermal neutron flux density
|
5·1018 m-2s-1
|
Average volumetric heat rate in the core
|
0.85 MW/l
|
Heat rate non-uniformity factor:
|
|
|
1.38 ÷ 1.74
|
Temperature
|
|
Coolant:
|
water
|
|
1.25 MPa
|
- reactor inlet temperature
|
30 ÷ 70оС
|
- reactor outlet temperature
|
Up to 98оС
|
Operating mode
|
|
Micro-run duration
|
Up to 40 days
|